2,879 research outputs found

    X-ray variability of the quasar 3C273

    Get PDF
    Observations of the quasar 3C273 made during 1975-77 have shown that the X-ray flux varied on a time scale of several months. No similar variation was present in radio and optical data taken at similar times. If this variation results from luminosity variations of a central compact object, then an upper limit of ≀4 x 1017cm can be set on its dimensions

    Preformed metal crowns for decayed primary molar teeth

    Get PDF
    BackgroundPreformed metal crowns (PMCs) are recommended by the British Society of Paediatric Dentistry (BSPD) for restoring badly broken down primary molar teeth. However, few dental practitioners adopt this technique in clinical practice, citing cost and clinical difficulty as reasons for this. Whilst there is a subjective impression by clinical academics that PMCs provide a more durable restoration than filling materials, there appears to be little evidence within the literature to support this.ObjectivesThe primary aim of this systematic review was to compare clinical outcomes for primary molar teeth restored using PMCs compared to those restored with filling materials.Search methodsThe literature was searched using: the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2005, Issue 3); MEDLINE (1966 to August 2005); EMBASE (1980 to August 2005); System for Information on Grey Literature in Europe (SIGLE) (1976 to August 2005). Relevant publications' reference lists were reviewed for relevant articles. The most recent search was carried out on 24 August 2005.Selection criteriaRandomised controlled trials (RCTs) that assessed the effectiveness of PMCs compared with filling materials or where there had been no treatment in children with untreated tooth decay in one or more primary molar teeth.Data collection and analysisTwo review authors independently assessed the title and abstracts for each article from the search results to decide whether it was likely to be relevant. Full papers were obtained for relevant articles and all three review authors studied these.Main resultsForty‐seven records were retrieved by the search strategies of which some were duplicates. Of these, 14 studies were scrutinised. No studies met the inclusion criteria and six studies were excluded from the review as they were either retrospective in design or reported as prospective outcomes but not randomised. No data were available for extraction and analysis and therefore, no conclusion could be made as to whether PMCs were more successful than filling materials for restoring primary molar teeth.Authors' conclusionsNo RCTs were available for appraisal. Whilst this technique is recommended by the BSPD for use in clinical practice, the evidence to support this is not strong, consisting mainly of case reports and uncontrolled studies. It is important that the absence of evidence for PMCs is not misinterpreted as evidence for their lack of efficacy.There is a strong need for prospective RCTs comparing PMCs and fillings for managing decayed primary molar teeth. The lower levels of evidence that have been produced, however, have strength in that the clinical outcomes are consistently in favour of PMCs, despite many of the studies placing PMCs on the most damaged of the pair of teeth being analysed

    Training health visitors in cognitive behavioural and person-centred approaches for depression in postnatal women as part of a cluster randomised trial and economic evaluation in primary care: the PoNDER trial

    Get PDF
    Aim: This paper aims to describe the training preparation for health visitors who took part in the intervention arm of a cluster randomised controlled trial and economic evaluation of training for health visitors – the POstNatal Depression Economic evaluation and Randomised (the PoNDER) trial. A secondary aim is to make available, by electronic links, the training manuals developed for and used for the cognitive behavioural approach (CBA) and the person-centred approach (PCA) training for the health visitors. The paper is of relevance to health visitors, general practitioners, nurse practitioners, midwives, clinical psychologists, mental health nurses, community psychiatric nurses, counsellors, and service commissioners. Background: The trial clinical outcomes have been published, indicating the pragmatic effectiveness of the package of training for health visitors to identify depressive symptoms and provide a psychologically informed intervention. The training was associated with a reduction in depressive symptoms at six months postnatally among intervention group women and some evidence of a benefit for the intervention group for some of the secondary outcomes at 18 months follow-up. Methods: The two experimental interventions examined in the PoNDER trial built upon promising work on the potential for psychological interventions to help women recover from postnatal depression as an alternative to pharmaceutical interventions and to address the limitations of previous research in the area. Findings: The package of health visitor training comprised the development of clinical skills in assessing postnatal women and identifying depressive symptoms, and the delivery of a CBA or a PCA for eligible women. This was the largest trial a health visitor intervention and of postnatal depression ever conducted. We are aware of no other rigorously performed trial that has published details of an extensively tested training programme for the benefit of health-care professionals and clients

    An in vitro comparison between two methods of electrical resistance measurement for occlusal caries detection

    Get PDF
    Because of different measurement techniques and the easier design of the CRM prototype, this in vitro study aimed to compare the diagnostic performance and reproducibility of two electrical methods (Electronic Caries Monitor III, ECM and Cariometer 800, CRM) for occlusal caries detection, and to evaluate the effect of staining/ discoloration of fissures on diagnostic performance. Hundred and seventeen third molars with no apparent occlusal cavitation were selected. Six examiners inspected all specimens independently, using the CRM, and a subgroup of 4 using the ECM. Histological validation using a stereomicroscope was performed after hemisectioning. Intra- and interexaminer reproducibility was assessed by Lin's concordance correlation coefficient (CCC) and Bland and Altman analysis. Diagnostic performance parameters included sensitivity (SE), specificity (SP) and area under the ROC curve (A(z)). The CCC yielded an intra- and interexaminer reproducibility of 0.69/0.62 (ECM) and of 0.79/0.74 (CRM). The mean intra- and interexaminer 95% range of measurements (range between Bland and Altman limits of agreement) given in percentages of the instrument reading were 67%/65% for the ECM and 28%/33% for the CRM. A(z) at the D3-4 level was 0.74 (ECM) and 0.78 (CRM). The CRM showed at least equivalent diagnostic performance to the ECM. However, improvement is still desirable. Diagnostic performance appeared to be enhanced in discolored lesions; however, this may be related to sample lesion distribution characteristics. Copyright (C) 2006 S. Karger AG, Basel

    An overview of aeroelasticity studies for the National Aerospace Plane

    Get PDF
    The National Aero-Space Plane (NASP), or X-30, is a single-stage-to-orbit vehicle that is designed to takeoff and land on conventional runways. Research in aeroelasticity was conducted by NASA and the Wright Laboratory to support the design of a flight vehicle by the national contractor team. This research includes the development of new computational codes for predicting unsteady aerodynamic pressures. In addition, studies were conducted to determine the aerodynamic heating effects on vehicle aeroelasticity and to determine the effects of fuselage flexibility on the stability of the control systems. It also includes the testing of scale models to better understand the aeroelastic behavior of the X-30 and to obtain data for code validation and correlation. This paper presents an overview of the aeroelastic research which has been conducted to support the airframe design

    Summerlin Masonry

    Get PDF
    Summerlin Masonry is a residential masonry company located in the Bryan-College Station, Texas Metropolitan Statistical Area (MSA). The company specializes in rock, both real and fake, brick, glass block, and tile work. Summerlin Masonry mainly works on houses in upper-middle class neighborhoods, but occasionally works on commercial jobs as favors to builders. The company has performed very well in its first two years of operation. While the company has been performing very well, it has not been without problems. Due to deceptive practices of his former partner when he was with B&S Masonry, the owner has become indebted to the IRS. They are holding him responsible for the entire debt of payroll tax checks that were not deposited, plus penalties and interest. After many months of communication with the IRS, the owner has begun to lower his debt and fully intends to repay the entire debt for his partner’s mishap. In the past two years, Summerlin Masonry has doubled its business. Due to the high demand for the business’s services, expansion into new locations and markets are being considered. (Contact author for a copy of the complete report.)Small Business Mgmt, Ethics

    Evaluation of four subcritical response methods for on-line prediction flutter onset in wind-tunnel tests

    Get PDF
    The methods were evaluated for use in tests where the flutter model is excited solely by airstream turbulence. The methods were: randomdec, power-spectral-density, peak-hold, and cross-spectrum. The test procedure was to maintain a constant Mach number (M) and increase the dynamic pressure (g) in incremental steps. The test Mach numbers were 0.65, 0.75, 0.82, 0.90, and 1.15. The four methods provided damping trends by which the flutter mode could be tracked and extrapolated to a flutter-onset q. A hard flutter point was obtained at M = 0.82. The peak-hold and cross-spectrum methods gave reliable results and could be most readily used for on-line testing. At M = 0.82, a p-k analysis predicted the same flutter mode as the experiment but a 6-percent lower flutter q. At the subcritical dynamic pressures, calculated damping values were appreciably lower than measured data

    Pilot Open Case Series of Voice over Internet Protocol-Delivered Assessment and Behavior Therapy for Chronic Tic Disorders

    Get PDF
    Comprehensive Behavioral Intervention for Tics (CBIT) is an efficacious treatment for children with chronic tic disorders (CTDs). Nevertheless, many families of children with CTDs are unable to access CBIT due to a lack of adequately trained treatment providers, time commitment, and travel distance. This study established the interrater reliability between in-person and Voice over Internet Protocol (VoIP) administrations of the Yale Global Tic Severity Scale (YGTSS), and examined the preliminary efficacy, feasibility, and acceptability of VoIP-delivered CBIT for reducing tics in children with CTDs in an open case series. Across in-person and VoIP administrations of the YGTSS, results showed mean agreement of 91%, 96%, and 95% for motor, phonic, and total tic severity subscales. In the pilot feasibility study, 4 children received 8 weekly sessions of CBIT via VoIP and were assessed at pre- and posttreatment by an independent evaluator. Results showed a 29.44% decrease in clinician-rated tic severity from pre- to posttreatment on the YGTSS. Two of the 4 patients were considered treatment responders at posttreatment, using Clinical Global Impressions–Improvement ratings. Therapeutic alliance, parent and child treatment satisfaction, and videoconferencing satisfaction ratings were high. CBIT was considered feasible to implement via VoIP, although further testing is recommended

    Transonic unsteady airloads on an energy efficient transport wing with oscillating control surfaces

    Get PDF
    An aspect ratio 10.8 supercritical wing with oscillating control surfaces is described. The wing is instrumental with 252 static orifices and 164 in situ dynamic pressure transducers for studying the effects of control surface deflection on steady and unsteady pressures at transonic speeds. Results from initial wind tunnel tests conducted in the Langley Transonic Dynamics Tunnel are discussed. Unsteady pressure results are presented for two trailing edge control surfaces oscillating separately at the design Mach number of 0.78. Some experimental results are compared with analytical results obtained by using linear lifting surface theory
    • 

    corecore